NFR-8 0.6/1kV

Products

NFR-8 1x 1.5mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 8.5 mm
  • Approximate weight: 65 kg/km

 

NFR-8 1x 2,5mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 9 mm
  • Approximate weight: 80 kg/km

 

NFR-8 1x 4mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 9.5 mm
  • Approximate weight: 10 kg/km

 

NFR-8 1x 6mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 10 mm
  • Approximate weight: 120 kg/km

 

NFR-8 1x 10mm²

Nexans ref. 84003608

  • Number of cores: 1
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 11 mm
  • Approximate weight: 190 kg/km

 

NFR-8 1x 16mm²

Nexans ref. 14006025

  • Number of cores: 1
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 12 mm
  • Approximate weight: 220 kg/km

 

NFR-8 1x 25mm²

Nexans ref. 14005963

  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 13.5 mm
  • Approximate weight: 310 kg/km

 

NFR-8 1x 35mm²

Nexans ref. 14006021

  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 430 kg/km

 

NFR-8 1x 50mm²

Nexans ref. 14007881

  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 545 kg/km

 

NFR-8 1x 70mm²

Nexans ref. 14007882

  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 740 kg/km

 

NFR-8 1x 95mm²

Nexans ref. 14007911

  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 1000 kg/km

 

NFR-8 1x 120mm²

Nexans ref. 14005969

  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 1250 kg/km

 

NFR-8 1x 150mm²

Nexans ref. 14017245

  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Outer Diameter: 25 mm
  • Approximate weight: 1530 kg/km

 

NFR-8 1x 185mm²

Nexans ref. 14005044

  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Outer Diameter: 27 mm
  • Approximate weight: 1900 kg/km

 

NFR-8 1x 240mm²

Nexans ref. 14005045

  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Outer Diameter: 30 mm
  • Approximate weight: 2460 kg/km

 

NFR-8 1x 300mm²

Nexans ref. 14013948

  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Outer Diameter: 33 mm
  • Approximate weight: 3040 kg/km

 

NFR-8 1x 400mm²

Nexans ref. 14021807

  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Outer Diameter: 36.5 mm
  • Approximate weight: 3850 kg/km

 

NFR-8 1x 500mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Outer Diameter: 41 mm
  • Approximate weight: 4930 kg/km

 

NFR-8 1x 630mm²

Nexans ref.

  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Outer Diameter: 46 mm
  • Approximate weight: 6340 kg/km

 

NFR-8 2x 1.5mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 14 mm
  • Approximate weight: 135 kg/km

 

NFR-8 2x 2,5mm²

Nexans ref. 84003694

  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 170 kg/km

 

NFR-8 2x 4mm²

Nexans ref. 84003695

  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 16 mm
  • Approximate weight: 210 kg/km

 

NFR-8 2x 6mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 17.5 mm
  • Approximate weight: 255 kg/km

 

NFR-8 2x 10mm²

Nexans ref. 84003639

  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 360 kg/km

 

NFR-8 2x 16mm²

Nexans ref. 14006540

  • Number of cores: 2
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 21 mm
  • Approximate weight: 480 kg/km

 

NFR-8 2x 25mm²

Nexans ref. 14008041

  • Number of cores: 2
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 680 kg/km

 

NFR-8 2x 35mm²

Nexans ref. 14007880

  • Number of cores: 2
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 930 kg/km

 

NFR-8 2x 50mm²

Nexans ref. 14008135

  • Number of cores: 2
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 30 mm
  • Approximate weight: 1180 kg/km

 

NFR-8 2x 70mm²

Nexans ref. 14008136

  • Number of cores: 2
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 34.5 mm
  • Approximate weight: 1660 kg/km

 

NFR-8 2x 95mm²

Nexans ref. 14041003

  • Number of cores: 2
  • Conductor cross-section: 95 mm²
  • Outer Diameter: 38 mm
  • Approximate weight: 2210 kg/km

 

NFR-8 2x 120mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 120 mm²
  • Outer Diameter: 42 mm
  • Approximate weight: 2735 kg/km

 

NFR-8 2x 150mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 150 mm²
  • Outer Diameter: 46.5 mm
  • Approximate weight: 3410 kg/km

 

NFR-8 2x 185mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 185 mm²
  • Outer Diameter: 51 mm
  • Approximate weight: 4200 kg/km

 

NFR-8 2x 240mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 240 mm²
  • Outer Diameter: 57.5 mm
  • Approximate weight: 5460 kg/km

 

NFR-8 2x 300mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 300 mm²
  • Outer Diameter: 63 mm
  • Approximate weight: 6750 kg/km

 

NFR-8 3x 1.5mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 170 kg/km

 

NFR-8 3x 2,5mm²

Nexans ref. 84003696

  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 16 mm
  • Approximate weight: 210 kg/km

 

NFR-8 3x 4mm²

Nexans ref. 84003538

  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 270 kg/km

 

NFR-8 3x 6mm²

Nexans ref. 84003763

  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 350 kg/km

 

NFR-8 3x 10mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 480 kg/km

 

NFR-8 3x 16mm²

Nexans ref. 14008318

  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 22 mm
  • Approximate weight: 650 kg/km

 

NFR-8 3x 25mm²

Nexans ref. 14017244

  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 930 kg/km

 

NFR-8 3x 35mm²

Nexans ref. 14006121

  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 28.5 mm
  • Approximate weight: 1240 kg/km

 

NFR-8 3x 50mm²

Nexans ref. 14005968

  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 32 mm
  • Approximate weight: 1600 kg/km

 

NFR-8 3x 70mm²

Nexans ref. 14006118

  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 37 mm
  • Approximate weight: 2230 kg/km

 

NFR-8 3x 95mm²

Nexans ref. 14006119

  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Outer Diameter: 41 mm
  • Approximate weight: 3020 kg/km

 

NFR-8 3x 120mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Outer Diameter: 45.5 mm
  • Approximate weight: 3860 kg/km

 

NFR-8 3x 150mm²

Nexans ref. 14042991

  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Outer Diameter: 50.5 mm
  • Approximate weight: 4790 kg/km

 

NFR-8 3x 185mm²

Nexans ref. 14042992

  • Number of cores: 3
  • Conductor cross-section: 185 mm²
  • Outer Diameter: 55.5 mm
  • Approximate weight: 5980 kg/km

 

NFR-8 3x 240mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 240 mm²
  • Outer Diameter: 62 mm
  • Approximate weight: 7730 kg/km

 

NFR-8 3x 300mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 300 mm²
  • Outer Diameter: 68 mm
  • Approximate weight: 9560 kg/km

 

NFR-8 4x 1.5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 16 mm
  • Approximate weight: 200 kg/km

 

NFR-8 4x 2,5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 250 kg/km

 

NFR-8 4x 4mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 330 kg/km

 

NFR-8 4x 6mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 430 kg/km

 

NFR-8 4x 10mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 610 kg/km

 

NFR-8 4x 16mm²

Nexans ref. 14006120

  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 820 kg/km

 

NFR-8 4x 25mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 28.5 mm
  • Approximate weight: 1200 kg/km

 

NFR-8 4x 35mm²

Nexans ref. 14006122

  • Number of cores: 4
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 31.5 mm
  • Approximate weight: 1600 kg/km

 

NFR-8 4x 50mm²

Nexans ref. 14018543

  • Number of cores: 4
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 35.5 mm
  • Approximate weight: 2105 kg/km

 

NFR-8 4x 70mm²

Nexans ref. 1404118

  • Number of cores: 4
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 41 mm
  • Approximate weight: 2990 kg/km

 

NFR-8 4x 95mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 95 mm²
  • Outer Diameter: 45.5 mm
  • Approximate weight: 4060 kg/km

 

NFR-8 4x 120mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 120 mm²
  • Outer Diameter: 50.5 mm
  • Approximate weight: 5050 kg/km

 

NFR-8 4x 150mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Outer Diameter: 56 mm
  • Approximate weight: 6300 kg/km

 

NFR-8 4x 185mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 185 mm²
  • Outer Diameter: 61.5 mm
  • Approximate weight: 7820 kg/km

 

NFR-8 4x 240mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 240 mm²
  • Outer Diameter: 69 mm
  • Approximate weight: 10180 kg/km

 

NFR-8 4x 300mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 300 mm²
  • Outer Diameter: 76 mm
  • Approximate weight: 12610 kg/km

 

Description

Description

Standards

  • National
    KS C IEC 60502-1; KWS 409

Application

Power cable for distribution circuit of residential, commercial building .
Fire resistant and low toxic cable.

 

Standard

K 60502-1

KS C IEC 60502-1

KWS 409: cable for Firefighting (Fire resistance)

KWS 410: 0.6/1kV Flame retardant power cable

 

Construction

1. Conductor: Annealed copper stranded conductor, Class 2

2. Insulation: Fire resistant: Mica tape.

3. Insulation: Cross-linked polyethylene (XLPE), Max. operating temperature 90°C

4. Unit: Cabling circularly insulated solid conductor in case of more than 2 cores

4. Outer sheath: Black low toxic and flame retardant Polyefin

 

Colors

1 core: Natural color (XLPE)
2 cores: White /Black
3 cores: White / Black /Red,
4 cores: White / Black / Red / Green

 

Certification

KETI, Korea Eco-Label

NFR-8 0.6/1kV design

##image:56211##

Conductor

Insulation

Filler

Binder tape

Outer sheath

 

The values of insulation resistance is not defined but only constant number of insulation resistance is defined. (K=min. 36.7MΩ.km at 90°C)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Annealed copper
Type of conductor
Stranded, class 2
Insulation
Micatape + XLPE
Outer sheath
LSZH

Electrical characteristics

Electrical characteristics

Test voltage
3500 V
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Corrosivity
IEC 60754-2

Usage characteristics

Usage characteristics

Operating temperature, range
-15 ... 90 °C
Flame retardant
KSC IEC 60332-3
Smoke density
ASTME 662
Bending factor when installed
12 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close